Your current location: Home - Product - WOODWARD

WOODWARD Discrete I/O Module 5464-554

This module is a simplex discrete input/output unit. This device is produced by Woodward and is part of the MicroNet digital control series, which can also be used with Vertex Pro chassis. The typical hardware used in this unit is MicroNet Plus hardware. This module can be used for both simplex and redundant systems. This module can be used for any chassis module, whether it is eight slots or fourteen slots. Please note that the location of this device must be non hazardous or within the range of Class I, Zone 2, Groups A, B, C, and D, with 48/24 discrete combination modules, which means there are 48 inputs and 24 outputs. This module has two configurations. One of them consists of two 24/12 discrete FTMs, which are connected to the module through two high-density discrete/analog cables. The discrete inputs on this module will be optically isolated and can be accessed through 24/12 FTMs in the second configuration.

¥564.00

¥854.00

PRODUCT TAGS

  5464-554- Discrete I/O modules are available in stock and will be shipped on the same day.

  5464-554- Discrete I/O module in unused and rebuilt state.

  To get the best discount on 5464-554-discrete I/O modules, please contact us and we will reply to you within 24 hours.


  5464-554 Other names:

  5464-554 functional modules

  Signal module 5464-554

  Control module 5464-554


  Woodward 5464-554 Simplex 48/24 Discrete I/O Module, suitable for MicroNet and Vertex Pro chassis. This device has one red fault LED and has been UL/ATEX certified. The 5464-554 device is part of the MicroNet digital controller Vertex Pro system.


  Product Description

  The 5464-554 module is a simplex discrete input/output unit. This device is produced by Woodward and is part of the MicroNet digital control series, which can also be used with Vertex Pro chassis. The typical hardware used in this unit is MicroNet Plus hardware. This module can be used for both simplex and redundant systems. This module can be used for any chassis module, whether it is eight slots or fourteen slots. Please note that the location of this device must be non hazardous or within the range of Class I, Zone 2, Groups A, B, C, and D.

  The 5464-554 module is a 48/24 discrete combination module, which means there are 48 inputs and 24 outputs. This module has two configurations. One of them consists of two 24/12 discrete FTMs, which are connected to the module through two high-density discrete/analog cables. The discrete inputs on this module will be optically isolated and can be accessed through 24/12 FTMs in the second configuration.

  There is only one LED on the front panel indicating a potential fault. There are also two connectors on the module. The 5464-554 module is considered outdated as Woodward no longer produces it, but it can still be found in new and second-hand surplus products. If you want to purchase this module,


  Function Description

  5464-554 is a discrete I/O module developed by Woodward. These modules are inserted into the card rails of the controller chassis and connected to the motherboard. Two screws (one at the top of the front panel and one at the bottom of the front panel) secure the module in place. There are also two handles at the top and bottom of the module, which, when moved (pushed outward), will move the module far enough to detach the motherboard from the motherboard connector.

  install

  Connect the input module to the appropriate network and 24 Vdc power supply and install it on the DIN rail. If necessary, the input can be wired using an internal+24V connection or an external 24V power supply. Connect discrete inputs.

  Set the module address one and ten rotary switches according to the application settings. The system allows for real-time replacement of faulty nodes. When replacing nodes, it is necessary to maintain good network cable connections.

  By removing the two terminal blocks from the connector and the node from the DIN rail, the faulty node can be disconnected from the network. The address switch of the replacement node should be set to match the address switch of the faulty node.

  Afterwards, the replacement node can be installed on the DIN rail and the terminal block can be pushed into the connector socket. To restart communication with the controller module and clear the no message fault, the node must be reset using the application program.


  Frequently asked questions

  What is 5464-554?

  It is a discrete I/O module developed by Woodward.

  How many discrete inputs does the module provide?

  This module provides sixteen discrete inputs for on-site switch or relay contacts.

  What voltage source is required for input?

  All 16 inputs of this module require a+24 Vdc power supply.

  Is internal power provided?

  Yes, this module is equipped with a filtered and fused internal power supply for discrete inputs.


  Comments 5464-554

  The 5464-554 module can be used in multiple chassis modules, one of which includes the Vertex Pro chassis.


  All products on this website are special products, and market prices have been fluctuating,

  The specific customer service quotation shall prevail, as the product is a new one and the traps are not real,

  Please confirm the model, product, price, and other detailed information with customer service before placing an order. The website has been used,

  New for sale, please contact the website https://www.axcontroler.com/ Customer service communication.


Same functional model:
5501-380
5466-1000
5466-017
5501-473
5466-419
5466-3321
5501-466
5501-432
5501-428
5501-367
5501-470
5501-381
5501-372
5501-371
5501-365
5501-003

PRODUCT TAGS

Shanxi Runsheng Import and Export Co., Ltd

Address: 3301, Building A, Wanda Center, No. 175 Jiefang Road, Xinghualing District, Taiyuan City, Shanxi Province
Google email: wkcarshop666888@gmail.com
Industrial Control Sales Consultant: Amelia
Whatsapp: +86 18030295882

Copyright © 2023~2024 Shanxi Runsheng Import and Export Co., Ltd