Built-in signal conditioning circuit: Internally completes charge-to-current conversion, eliminating the need for an external charge amplifier; unlike ordinary IEPE voltage output, it uses current-modulated two-wire output, ensuring attenuation over long distances. Employing two-wire current output, it is suitable for long-distance vibration protection monitoring of explosion-proof units; the integrated circuit simplifies monitoring system wiring and reduces intermediate connection failure points.

PRODUCT TAGS

  Many products are not yet listed. Please contact us for more product information.

  If the product model differs from the displayed image, the model number shall prevail. Please contact us for specific product images; we will arrange to take photos in our warehouse for confirmation.

  We have 76 shared warehouses worldwide, so it may sometimes take several hours to accurately return the information to you. We apologize for the inconvenience. Of course, we will respond to your inquiries as soon as possible.


  I. Core Structure and Working Principle

  1. Sensing Core: Symmetrical shear mode polycrystalline piezoelectric element, with an integrally insulated shell to eliminate ground loop interference and resist industrial electromagnetic noise.

  2. Built-in Signal Conditioning Circuit: Internally completes charge-to-current conversion, eliminating the need for an external charge amplifier; unlike ordinary IEPE voltage output, it adopts current modulation two-wire output, ensuring no attenuation over long distances. The two-wire current output is suitable for long-distance vibration protection monitoring of explosion-proof units.

  3. Outgoing Cable Protection: Standard configuration includes a stainless steel corrugated pipe integrated sealed cable, completely waterproof, lubricating oil, steam, and coolant-resistant, suitable for installation in unit oil tanks and high-temperature chambers.


  II. Core Product Advantages

  1. Stable Long-Distance Transmission: Compared to IEPE voltage type, current output results in minimal cable voltage drop and interference, eliminating the need for repeaters in cross-regional cabling within large steam turbine rooms.

  2. Intrinsically Safe Explosion-Proof Standard: The 143-103-000-502 Ex version possesses complete explosion-proof certification, allowing direct installation in high-risk areas such as natural gas compressors, refining units, and gas turbines.

  3. Harsh Working Condition Protection: Metal-sealed corrugated conduit outlet, resistant to oil, water vapor, and dust, suitable for long-term 24/7 online monitoring.

  4. Built-in Insulation and Interference Resistance: The sensor housing is isolated from the measurement circuit, ensuring no noise drift in vibration data under strong electromagnetic environments such as power plants and frequency converter rooms.

  5. No External Signal Conditioning Required: Integrated circuitry simplifies monitoring system cabling and reduces intermediate connection failure points.


  III. Typical Application Scenarios (Power/Petrochemical Core Equipment)

  1. Vibration monitoring and shutdown protection interlocking for heavy-duty gas turbine and steam turbine bearing housings.

  2. Condition monitoring for large reciprocating/centrifugal compressors and booster units.

  3. Predictive maintenance for high-power fans, gearboxes, and pump sets.

  4. Online monitoring of rotating machinery in explosion-proof areas such as oil refining, coal chemical, and LNG plants.

  5. Vibration protection systems for steam turbine generator sets and feedwater pumps in power plants.


  IV. Supporting System Configuration

  Backend Data Acquisition: Vibro-Meter VM600, Meggitt VibroSmart, and various unit vibration protection devices.

  Wiring: Two-core shielded twisted-pair cable, both lines supply power and transmit vibration current signals simultaneously.


  V. Installation and Wiring Points

  Installation Thread Standard: 1/4"-28 UNF, Tightening Torque 2.4 N·m

  Two-wire connection: The power and signal lines share a shielded twisted pair cable, with the shield grounded at one end.

  Back-end data acquisition: Must be used with a vibration rack with a current input channel (VM600 card dedicated channel); do not directly connect to the IEPE voltage input channel.

  Installation requirements: The sensor base must be fully flush with the metal surface of the equipment, tightened to the specified torque, avoiding soft installation of the shims which reduces high-frequency response.


Recommended related products:
CE31X 444-311-000-302
CE31X 444-311-000-213
CE31X 444-311-000-212
CE31X 444-311-000-203
CE31X 444-311-000-123
CE31X 444-311-000-202
CE31X 444-311-000-122
CE31X 444-311-000-113
CE31X 444-311-000-112
CE31X 444-311-000-301
CE28X 444-281-000-213
More......

PRODUCT TAGS

RELATED PRODUCTS

PLC Dragon Automation

Address: Wanda Plaza, Chengdu, Sichuan Province
Google email: wkcarshop666888@gmail.com
Industrial Control Sales Consultant: Amelia
Whatsapp: +86 18030295882

Copyright © 2023~2024 PLC Dragon Automation