F3322 | HIMA | 8 fold Output module, safety related
The controller is equipped with 8 digital outputs. The state (HIGH, LOW) of each output is signaled by an individual LEDAt the maximum ambient temperature, each of the outputs 1...3 and 5...7 can be loaded with 0.5 A, and outputs 4 and 8 can be loaded with 1 A or 2 A at an ambient temperature of up to 50 °C. If an overload occurs, one or all outputs are switched off. If the overload is removed, the outputs are switched on again automatically, see Table 28. The external wire of an output is not monitored, however, a detected short-circuit is signaled.
Many products have not been listed yet. For more products, please contact us
If the product model is inconsistent with the displayed image, the model shall prevail. Please contact us for specific product images, and we will arrange for photos to be taken and confirmed in the warehouse
We have 16 shared warehouses worldwide, so sometimes it may take several hours to accurately return to you. We apologize for any inconvenience caused. Of course, we will respond to your concerns as soon as possible.
Product
Description
The safety-related F35 controller is a compact system located in a metal enclosure with 24 digital inputs, 8 digital outputs, 2 counters and 8 analog inputs.
The controller is available in 3 model variants for SILworX and 3 model variants for ELOP II Factory, see Chapter 3.2. All variants are described in this manual.
The device is suitable for mounting in Ex-zone 2, see Chapter 4.1.5.
The device has been certified by the TÜV for safety-related applications up to SIL 3 (IEC 61508, IEC 61511 and IEC 62061), Cat. 4 (EN 954-1) and PL e (EN ISO 13849-1). Further safety standards, application standards and test standards are specified in the certificate available on the HIMA website.
Safety
Function
The controller is equipped with safety-related digital inputs and outputs, safety-related counters and safety-related analog inputs.
Safety-Related Digital Inputs
The controller is equipped with 24 digital inputs. The state (HIGH, LOW) of each input is signaled by an individual LED.
The input signals are captured as analog measurements and provided to the program as a range of INT values from 0...3000 (0...30 V). Configurable thresholds are used to generate BOOL values, see Table 26
Reaction
in the Event of a Fault
If the device detects a fault on a digital input, the user program processes a low level in accordance with the de-energized to trip principle.
In addition to the channel signal value, the user program must also consider the corresponding error code. The error code allows the user to configure additional fault reactions in the user program.
Safety-Related
Digital Outputs
The controller is equipped with 8 digital outputs. The state (HIGH, LOW) of each output is signaled by an individual LED
At the maximum ambient temperature, each of the outputs 1...3 and 5...7 can be loaded with 0.5 A, and outputs 4 and 8 can be loaded with 1 A or 2 A at an ambient temperature of up to 50 °C. If an overload occurs, one or all outputs are switched off. If the overload is removed, the outputs are switched on again automatically, see Table 28. The external wire of an output is not monitored, however, a detected short-circuit is signaled.
Line
Monitoring for Digital Outputs
The analog inputs can be used to monitor the digital outputs for short-circuits and opencircuits.
Figure 3 shows a circuitry for line monitoring (open circuits and short-circuits) that complies with SIL 3. Additionally, the S1 supply voltage is monitored via a digital input DI. In this application, the actuator (e.g., solenoid valve) is connected to the digital output between DO and L-. All specified electronic components must be directly attached to the clamps. The reaction to open-circuits and short-circuits must be configured in the user program
Product
Data HIMatrix F35 012 (Subsea / -20 °C)
The HIMatrix F35 012 model variant is intended for subsea-use according to ISO 13628 Part 6: Subsea production control systems. The electronic components are coated with a protective lacquer. The enclosure of the controller is made of V2A stainless steel. The controller is intend for mounting on a mounting plate. The enclosure is equipped with a massive aluminum plate, see Figure 8. Figure 9 specifies the centre hole distances
All products on this website are special products, and market prices have been fluctuating,
The specific customer service quotation shall prevail, as the product is a new one and the traps are not real,
Please confirm the model, product, price, and other detailed information with customer service before placing an order. The website has been used,
The new one is for sale, please contact customer service to communicate.
Warehouse discount product
recommendation:
PEES
COMPONENTS AN528 SERVO AMPLIFIER CARD
GE
Digital I/O board IS200TSVOH1A
HITECH
INSTRUMRNTS G1010 OXYGEN ANALYSER
F3DIO20/802
F6214
F6215
F7130A
F7126
F7131
981713102
F7553
984755302
HIMA CPU
processor F8621A
F8621A
984862160
HIMA CPU
processor F8627
HIMA
CPU processor F8627X 984862702
F8627
984862702
HIMA CPU
processor F8650X
F8651X
984865165
F8650X
984865065
HIMA CPU
processor F8652X
HIMA
CPU processor F8652X 984865265
PRODUCT TAGS
Shanxi Runsheng Import and Export Co., Ltd
Address: 3301, Building A, Wanda Center, No. 175 Jiefang Road, Xinghualing District, Taiyuan City, Shanxi Province
Google email: wkcarshop666888@gmail.com
Industrial Control Sales Consultant: Amelia
Whatsapp: +86 18030295882