GE WESTERM D20 M D20 D200 Substation Controllers
D20 Chassis (single-slot, non-VME)
The D20 chassis is a 3U horizontal slot chassis. The non-VME version of
the D20 chassis is equipped with a rear-mounted termination board that
provides power connection and serial port access to the D20 system.
Non-VME versions of the D20 provide a single horizontal Eurocard slot, into
which the D20ME board is installed.
Many products have not been listed yet. For more products, please contact us
If the product model is inconsistent with the displayed image, the model shall prevail. Please contact us for specific product images, and we will arrange for photos to be taken and confirmed in the warehouse
We have 16 shared warehouses worldwide, so sometimes it may take several hours to accurately return to you. We apologize for any inconvenience caused. Of course, we will respond to your concerns as soon as possible.
MultilinD20/D200 Substation
Controllers Simple to Advanced Substation Automation Control The Multilin
D20/D200 Substation Controllers offer an industry leading design embedded with
high value substation automation applications that provide cost savings,
increased reliability, and improved operational efficiencies in electric power
substations. The ability to support a wide range of communication protocols and
applications,
allows
the D20 to be interoperable with a broad range of intelligent electronic slave
and master devices. The D20 can execute simple to complex local logic, compile
and process data [collect and convert] and reports upstream to master stations.
The D20’s distributed, expandable I/O architecture
and mission-critical automation control applications reinforce why the D20
controller is being used in over 40,000 installations around the world. Key
Benefits In a mission-critical substation-hardened package, the D20/D200
provides:https://www.axcontroler.com/
•Substation client and server functionalities by maintaining a
distributed architecture for gathering and controlling data on substation
equipment while sending data to master stations via serial RS-232, RS-485, fibre
optic or Ethernet interfaces for point to point, multi-drop and remote
connections.
•Support for a broad range of SCADA host protocols, IED
protocols, Communication options, Input/output (I/O) peripheral modules, and
operation and maintenance utilities substation automation applications. Refer to
the hardware manual and see the appendix section of this document for more
details. Applications Functionalities such as data concentrator, protocol
converter or a local automation platform to implement popular distribution
automation applications such as capacitor bank control, outage prevention
programs, feeder resource optimization and control interlocking inhibition and
subgrouping. Functionalities such as data concentrator, protocol converter or a
local automation platform to implement popular distribution automation
applications such as capacitor bank control, outage prevention programs, feeder
resource optimization and control interlocking inhibition and subgrouping.
•Data Concentrator Automatically consolidates collected information from
intelligent electrical devices (IEDs), such as relays and meters, and
communicates to SCADA, EMS, DMS and Data Historian systems
•Protocol
Converter Translates different data message formats between devices to support
interoperability
•Local Automation Platform Implements popular distribution
automation applications such as capacitor bank control, outage prevention
programs, feeder resource optimization and control interlocking, inhibition and
subgrouping
Substation Controller Connectivity
The D20/D200 can support a wide range of substation automation communication
protocols and enhanced SCADA applications. See Appendix B for a list of
supported protocols for both client and server devices. The following summarizes
some of the different data translation applications that are equipped in the
D20/D200. Multilin D20/D200 Data Translation Applications User Programmable
Logic:
•LogicLinxmodule: IEC61131-3 compliant PLC-type logic with full
support for 5 programming languages
•Calculator module: Soft logic utility
to perform mathematical and logical operations Generation, Transmission, and
Feeder Bay Automation Applications: •
Automatic Voltage Control module: Maintains steady voltage base on user-defined
targets and settings •Local / Remote Data Translation module: A master
local/remote switch to control the local/remote state of distributed
devices
•Secondary Master Trip/Close module: Enables the use of individual
relays (with external terminations) as master trip/close relays
•Set-point
Adjustment module: Adjust set points based on control request durations or
analog input values
•Tap Position Indication module: Translates status
points into scaled analog input values to reflect transformer tap
positions Distribution
Automation Applications:
•Auto Reclose: Automatically
reclose tripped circuit breakers following momentary faults • Automatic
Restoration: Patented load transfer scheme isolates faults and restores power to
non-faulted sections if possible
•Distribution Capacitor Control
Algorithm: Improves reactive support during peak
periods through more effective use of existing capacitor banks
•Fault
Localization: Locates and isolate faults to reduce
customer outage times
•Load and
Dead Bus Transfer: Monitors a network of
substations and move load off overloaded transformers to other stations as
required
•Load
Shedding/Curtailment: Sheds load intelligently
during overload conditions Data Logging / Storage Applications:
•SOE Local
Logger: Logs digital and analog SOEs to an external
printer, PC or to a CSV file
•Accumulator Freeze: Coordinates freezing of
accumulator groups
•Event
Storage: Stores history of current values, status,
and time-tags of analogs and accumulators for up to 7 days
•Historical
Analog: Stores averaged historical values for up to
8 analog inputs Communication Services Applications:
•Communication
Watchdog: Monitors and report the health of
communications
•Substation
Maintenance: Suppresses SCADA point reporting
during substation maintenance
•Virtual Terminal: Directs remote access to
connected devices
•Line
Switch: Monitors main and secondary communication
channels and retransmits on a third channel
•LAN
Services: TFTP, SPT Server/Client, Time
Server/Client
•COM
Statistics: Records a detailed communication
pass/fail statistics
•IRIG B
Source: Time sync connected devices using
IRIG-B
•SNTP
Client: Time sync over an Ethernet LAN Data
Reduction and Summarizing Applications:
•Analog
Reference: Monitors analog input hardware for good
or bad reference values
•Data
Change Detect: Toggles a status point every time
any data in a configured group changes
•Alarm
Prioritization: An alarm filter designed to manage
the 3 level alarms reported by GE’s DART pole-top/pad-mount distribution
RTU
•Analog
Averaging: Averages analogs at regular
intervals
•General
Alarm: Groups alarms together to create summary
alarms
•Top of Hour (TOH) Analog
Averaging: Averages analogs at regular intervals
relative to the top of the hour • Redundant I/O: Provides data from a backup
source if the primary source is off-line Data Conversion Applications:
•Digital-Analog Value
Conversion: Converts digital input groups to analog
data using binary, BCD, or gray code encoding
•Digital Input to
Counter: Counts the number of SOE or COS
transitions on status points
•BCD
Setpoint: Translates analog output requests into a
group of BCD encoded control points • Accumulator Delta to Analog: Converts
accumulators to analog values for protocols that do not support
counters
•Time
Stamp: Interprets each bit in an analog input as a
status point, and create SOEs appropriately
•Analog to Digital
Conversion: Converts analog inputs into groups of
binary coded control outputs
•Mailbox: Converts analog outputs
into analog inputs so they can be read by all
masters https://www.axcontroler.com/
Configuration
and Maintenance Facility The D20/D200 is equipped with a range of maintenance
utilities to assist the user in configuring, testing and monitoring the system.
ConfigPro ConfigPro is a tool, installed on a personal computer, which helps you
manage information associated with your GE Energy equipment. The primary use of
ConfigPro is to facilitate the configuration of D20/D200 hardware and software
through the maintenance port on the main processor and I/O peripheral.
Information is accessed through a hierarchy of windows, as
follows:
Project Window: Provides a graphical
representation of your project. Each device in the project is represented by a
corresponding icon. Connections between devices are shown by a series of lines
and arrows.
Device Window: When you
double-click on a device, the device window is opened in the main area. The
device window will display all of the configurable applications for the
device.
The device window has four
tabs:
•Data collection applications
•Data
translation applications
•System point database
applications
•Data
processing applications Application
Window: Displays the tables for a particular
application Report Window: Allows you to select and print reports. SGConfig
SGConfig is the latest software used to configure D20/D200. SGConfig
replaces ConfigPro because it supports Windows 7 - 32 and 64-bit operating
systems while maintaining backwards compatibility with Windows XP. It is a PC
software-based user interface that allows users of GE Substation Gateways to
efficiently manage configuration files for the RTUs series of Substation
controllers. SGConfig includes all of the functionality available in the
ConfigPro software, provides enhanced visual representation of your substation
hardware configuration and device software configuration. In addition to the
ConfigPro functionality, SGConfig provides support for::
•Importing
and exporting xml representation of D2x devices
•D25 KT control card
•D25 Ethernet 100/10 MB card
•Secure configuration transfer to/from D20
devices with D20MX processors over Ethernet connections.
D200 Chassis (multiple-slot, VME]
The D200 chassis is equipped with a rear-mounted termination board for
power connections and serial-port access.
The D200 has the computing power and expandability needed to provide
substation automation in larger substations. This is achieved through an
innovative design that employs multiple D20 processors, communicating
over a VME bus:
• RS-232/RS-485 ports support large numbers of host systems and IEDs
• VME bus architecture provides high scalability and performance for
adding serial ports, LAN options, and memory
• Data is integrated and coordinated, so different applications access a
single, real-time database
• Optional redundant configuration for high reliability at critical sites
• ironment, in accordance with applicable IEEE® and IEC® standards
D200 hardware is similar in design to the D20 hardware, but it has
significantly more physical capacity. Based on a 9-slot VME chassis, the
D200 illustrated in figure 4 can support up to:
• 4 D.20 ports, each supporting up to 31 I/O peripherals, without repeaters,
and 120 I/O peripherals, with repeaters
• 49 RS-232 or RS-485 ports (seven per D20ME or D20ME II Main Processor)