FOXBORO FBM222 Analog/Digital Interface Module
Modules can be removed/replaced without the need to remove on-site equipment termination cables, power or communication cables. The light-emitting diode (LED) at the front of the module provides visual status indication of the fieldbus module (FBM) function. The module is installed on a modular substrate or conversion mounting structure and can accommodate up to four or eight FBMs. The modular motherboard adopts DIN rail installation or rack installation, including signal connectors for redundant fieldbuses, redundant independent DC power supplies, and terminal cables. The analog channel of FBM is isolated from all other channels and grounded (grounded). The digital channel of FBM is isolated in pairs with all other channels and grounding (grounding). The module/TA bears the potential of 600 V AC on the analog channel or 1250 V AC on the digital channel (1) without damage (see note below), which is applied for one minute between any channel and ground or between a given channel and any other channel.
Many products have not been listed yet. For more products, please contact us
If the product model is inconsistent with the displayed image, the model shall prevail. Please contact us for specific product images, and we will arrange for photos to be taken and confirmed in the warehouse
We have 16 shared warehouses worldwide, so sometimes it may take several hours to accurately return to you. We apologize for any inconvenience caused. Of course, we will respond to your concerns as soon as possible.
FBM227,
0 to 10 V DC, Contact/DC I/O Module with DPIDA and MDACT
Support
OVERVIEW
The FBM227 module provides signal conversion required to interface analog and digital electrical input/output signals from field sensors/actuators. It has four 0 to 10 V DC analog input channels and two 0 to 10 V DC analog output channels, all of which are individually isolated. For the digital I/O signals (on/off state), it has four digital input channels, isolated in two groups of two channels each, and four digital, pair isolated, output channels.It executes either the Analog I/O or Digital I/O application program, and has support for MDACT or DPIDA control.
The
configurable options for each analog program are
Input Resolution, Fail-safe Configuration (Hold/Fallback) and Output Fail-safe
Fallback Data. The configurable options for each digital program are Input
Filter Time, Fail-safe Configuration, Fail-safe Fall Back and Sustained or
Momentary Outputs. If the Momentary Output configuration is
selected, then Pulse Output Interval is also configurable.Configurable options
for inputs are exercised on a per module basis; those for outputs are exercised
on a per channel basis.
STANDARD
DESIGN
The FBM227 module has a rugged extruded aluminum exterior for physical protection of the circuits. Enclosures specially designed for mounting the FBMs provide various levels of environmental protection, up to harsh environments per ISA Standard S71.04.
EASY
REMOVAL/REPLACEMENT
The modules can be removed/replaced without removing field device termination cabling, power or communications cabling.
VISUAL
INDICATORS
Light-emitting diodes (LEDs) incorporated into the front of the modules provide visual status indications of Fieldbus Module (FBM) functions.
MODULAR
BASEPLATE MOUNTING
The modules mount on a modular baseplate or conversion mounting structure which accommodates up to four or eight FBMs. The modular baseplate is either DIN rail mounted or rack mounted, and includes signal connectors for redundant fieldbus, redundant independent DC power, and termination cables.
FIELDBUS
COMMUNICATION
A Fieldbus Communication Module or a Control Processor communications with the FBM227 over the redundant 2 Mbps module Fieldbus used by the FBMs. The FBM227 module accepts communication from either path (A or B) of the redundant 2 Mbps fieldbus – should one path fail or be switched off at the system level, the module continues communication over the active path.
TERMINATION
ASSEMBLIES
Field I/O signals connect to the FBM subsystem via DIN rail mounted TAs. The TAs used with the FBM227 modules are described in “TERMINATION ASSEMBLIES AND CABLES” on page 8.
Input
Channel Isolation
The FBM’s analog channels are channel isolated from all other channels and earth (ground). The FBM’s digital channels are isolated in pairs from all other channels and earth (ground). The module/TA withstands, without damage, a potential of 600 V AC on the analog channels or 1250 V AC on the digital channels(1) (see notes below) applied for one minute between any channel and ground, or between a given channel and any other channel.
TERMINATION
ASSEMBLIES AND CABLES
Field signals connect to the FBM subsystem via DIN rail mounted Termination Assemblies. TAs for the FBM227 module are available in the following forms:
Compression screw type using Polyamide (PA) material See “FUNCTIONAL SPECIFICATIONS – TERMINATION ASSEMBLIES” below for a list of TAs used with the FBM227 modules
A removable termination cable connects the DIN rail mounted TA to the FBM via a field connector on the baseplate in which the FBM is installed. Termination cables are available in the following materials:
Polyurethane Low Smoke Zero Halogen (LSZH). Termination cables are available in a variety of lengths, up to 30 meters (98 feet), allowing the Termination Assembly to be mounted in either the enclosure or in an adjacent enclosure. See Table 3 for a list of termination cables used with the TAs for the FBM227 modules.
Warehouse discount product
recommendation:
FOXBORO
P0400GH
FOXBORO
P0400DL
FOXBORO
P0400BJ
FOXBORO
P0400TH-F
FOXBORO
P0400VE
IS200SDIIH1ADB
IS200SDIIH1ADB
IS200SPIDG1ABA
IS215UCVEH2AB
HIMA F7131
981713102
EMERSON
A6500-TP
EPRO
MMS6120
BENTLY
163179-01
BENTLY
3500/60
60M100
84152-01
XVC768115
3BHB007211R115
PRODUCT TAGS
Shanxi Runsheng Import and Export Co., Ltd
Address: 3301, Building A, Wanda Center, No. 175 Jiefang Road, Xinghualing District, Taiyuan City, Shanxi Province
Google email: wkcarshop666888@gmail.com
Industrial Control Sales Consultant: Amelia
Whatsapp: +86 18030295882