Your current location: Home - Product - ABB

DSPU131 | ABB | Module for Engineering Station | DSPU131

The DSPU131 3BSE000355R1 engineering station module is used for Advant OCS with main software, mainly responsible for defining and maintaining the devices and their point table information parameters used in the relay protection engineer system. The specific work includes defining device parameters and device information point table parameters, such as analog parameters, switch parameters, SOE parameters, fixed value area parameters, pressure plate parameters, CPU parameters, and recording parameters.

PRODUCT TAGS

  Many products have not been listed yet. For more products, please contact us

  If the product model is inconsistent with the displayed image, the model shall prevail. Please contact us for specific product images, and we will arrange for photos to be taken and confirmed in the warehouse

  We have 16 shared warehouses worldwide, so sometimes it may take several hours to accurately return to you. We apologize for any inconvenience caused. Of course, we will respond to your concerns as soon as possible.


  Other names for DSPU131:

  Main control board DSPU131

  DSPU131 input/output module

  Analog controller DSPU131

  DSPU131 driver motherboard

  The DSPU131 engineer station module plays a crucial role in industrial automation and control systems. Its main function includes downloading configuration files and algorithm modules to the on-site control station to achieve configuration and control of on-site equipment.


  Detailed overview of the engineer station module:

  System hardware configuration configuration: involves the registration and management of on-site devices, including site configuration, system configuration, board configuration, and control point configuration, to ensure correct connection and communication between devices.

  Algorithm control configuration: Configure the algorithms of control points to ensure independence between basic algorithm modules, and form complex algorithms based on configuration information to meet specific control requirements.

  Compile and download: Compile the control algorithm module into a DLL file and generate an XML file with configuration information for use in the system.

  Data maintenance module: used to define and maintain the devices and their point table information parameters used in the relay protection engineer system, including analog parameters, switch parameters, etc.

  Relay protection processing module: responsible for monitoring the status, setting value management, pressing plate on/off and other operations of the protection devices in the substation system, ensuring the normal operation of the protection devices.

  Recording analysis module: Collect fault waveform data through a recording device, and use recording analysis software to analyze and study faults to support fault diagnosis and system optimization.

  Independence: Each module is relatively independent during development, but the order of the configuration process needs to be considered after operation.

  Flexibility: Engineers can configure different algorithms and control strategies according to actual needs to meet different production process requirements.

  Efficiency: Through centralized management and control, the engineer station module can greatly improve the operational efficiency and stability of the system.


  DSPU131 system hardware configuration configuration:

  The DSPU131 engineer station is responsible for registering and managing on-site equipment, including site configuration, system configuration, board configuration, and control point configuration.

  It defines the unique identification and other related information of the device, ensuring that all hardware components in the system can correctly identify, communicate, and work together.

  DSPU131 algorithm control configuration:

  The DSPU131 engineer station provides algorithm configuration functions for control points. This involves selecting or creating control algorithms and applying them to specific control points in the system.

  The basic algorithm modules of DSPU131 are completely independent, but engineers can combine them as needed to form more complex control strategies.

  Compilation and installation:

  The DSPU131 engineer station compiles control algorithm modules into executable files (such as DLL files) and generates XML files with configuration information.

  The XML file contains key data such as hardware configuration hierarchy, related interface parameters, and algorithm configuration information.

  Data maintenance:

  In some systems, the engineer station is also responsible for data maintenance functions, such as defining and maintaining the devices and their point table information parameters used in the relay engineer system.

  This includes analog parameters, switch parameters, SOE parameters, constant value zone parameters, pressure plate parameters, CPU parameters, and recording parameters.

  Relay protection processing and waveform analysis:

  The DSPU131 engineer station may also include a relay protection processing module, which is used to monitor the status of protection devices, perform fixed value management, enable/disable pressure plates, and query protection action reports.

  The waveform analysis module collects fault waveform data through the waveform recording device and conducts in-depth research on the fault file using analysis software.

  Offline configuration and online monitoring:

  The DSPU131 engineer station utilizes configuration software to perform offline configuration work on the DCS system, and can also supervise, control, and maintain the system during DCS operation without affecting process control.

  This enables engineers to perform system configuration, troubleshooting, and optimization adjustments without interrupting production.

  System security and maintenance:

  The DSPU131 engineer station is also responsible for ensuring the security and reliability of the system, including security measures such as access control, data encryption, and logging.

  It also provides maintenance and diagnostic tools to help engineers quickly identify and resolve system issues.

  Application:

  The DSPU131 engineer station module is widely used in industrial automation, power systems, petrochemical and other fields, providing strong support for enterprise production and management.

  Overall, the DSPU131 engineer station module is an important component of industrial automation and control systems. Through its powerful functions and flexible configuration methods, it brings great convenience and benefits to the production and management of enterprises.


  All products on this website are special products, and market prices have been fluctuating,

  The specific customer service quotation shall prevail, as the product is a new product and the price is not genuine,

  Please confirm the model, product, price, and other detailed information with customer service before placing an order. The website has been used,

  The new one is for sale, please contact customer service to communicate.


Warehouse discount product recommendation:
GVC707AE01 3BHB003149P201

3BHB003689 ABB
PM665 3BDS005799R1
LXN1604-6 3BHL000986P7000
CI522AK05 3BSE018452R1

CI522AK04 3BSE018451R1
CI522AK02 3BSE018449R1
CI522AK01 3BSE018448R1
CI534V02 3BSE010700R1
CI532V03 3BSE003828R1
CI532V01 3BSE003826R1
CI532V02 3BSE003827R1
CI532V09 3BUP001190R1
CI534V02 3BSE010700R1
CI535V26 3BSE022161R1
CI541V1 3BSE014666R1
More.......

PRODUCT TAGS

Shanxi Runsheng Import and Export Co., Ltd

Address: 3301, Building A, Wanda Center, No. 175 Jiefang Road, Xinghualing District, Taiyuan City, Shanxi Province
Google email: wkcarshop666888@gmail.com
Industrial Control Sales Consultant: Amelia
Whatsapp: +86 18030295882

Copyright © 2023~2024 Shanxi Runsheng Import and Export Co., Ltd