Your current location: Home - Product - ABB

3BHB006716R0217 | ABB | synchronous device | 3BHB006716R0217

During the operation of the power system, it is often necessary to parallel operate two different systems, and this parallel operation is called synchronous operation. Inappropriate parallelism can cause impacts on various components of the system, potentially causing system oscillations, relay protection actions such as current, voltage, and impedance, and posing a threat to the safe operation of the power grid and units. The synchronous device is an advanced synchronous grid connection device developed by ABB, aimed at ensuring the safe and accurate parallel operation of the generator or power system during the grid connection process. This device is suitable for power plants or industrial production equipment with built-in power generation facilities, especially suitable for situations where the generator needs to be connected to an isolated or public power grid. The device can adjust the speed and voltage of the generator to be connected, making it close to the system voltage and frequency, ensuring that the generator outlet circuit breaker is closed at the time of zero phase angle difference. This device achieves fast synchronization and grid connection of the generator. The device adopts a quasi synchronous method, that is, before being integrated into the power grid, the generator speed and excitation device are adjusted to make the generator speed and voltage close to the system value, and the generator outlet circuit breaker is selected to close at the time of zero phase angle difference, ensuring that the generator is quickly pulled into synchronous operation under the condition of minimum impulse current.

PRODUCT TAGS

  Many products have not been listed yet. For more products, please contact us

  If the product model is inconsistent with the displayed image, the model shall prevail. Please contact us for specific product images, and we will arrange for photos to be taken and confirmed in the warehouse

  We have 16 shared warehouses worldwide, so sometimes it may take several hours to accurately return to you. We apologize for any inconvenience caused. Of course, we will respond to your concerns as soon as possible.


  3BHB006716R0217 Other names:

  Synchronous device 3BHB006716R0217

  3BHB006716R0217 synchronous module

  Synchronous module 3BHB006716R0217

  3BHB006716R0217 synchronous device is a product of ABB company, mainly used for grid connection operation in power systems.


  Function introduction of 3BHB006716R0217 synchronous device:

  Product Overview:

  The importance of synchronous operation: During the operation of the power system, it is often necessary to parallel operate two different systems, and this parallel operation is called synchronous operation. Inappropriate parallelism can cause impacts on various components of the system, potentially causing system oscillations, relay protection actions such as current, voltage, and impedance, and posing a threat to the safe operation of the power grid and units. The 3BHB006716R0217 synchronous device is an advanced synchronous grid connection device developed by ABB, aimed at ensuring safe and accurate parallel operation of the generator or power system during the grid connection process. This device is suitable for power plants or industrial production equipment with built-in power generation facilities, especially suitable for situations where the generator needs to be connected to an isolated or public power grid.

  Main functions:

  Synchronous operation: The 3BHB006716R0217 synchronous device can adjust the speed and voltage of the standby generator to approach the system voltage and frequency, ensuring that the generator outlet circuit breaker is closed at zero phase angle difference, achieving fast synchronous grid connection of the generator.

  Monitoring and protection: The 3BHB006716R0217 synchronous device ensures the safety and accuracy of grid connection operation by real-time monitoring of parameters such as voltage, frequency, and phase angle difference on both sides. When the synchronization conditions are not met, the device will prevent the power circuit breaker from closing, avoiding impact on the power grid and the unit.

  Technical features:

  Accuracy: The 3BHB006716R0217 synchronous device adopts advanced algorithms and sensor technology, which can provide accurate and reliable measurement results.

  Reliability: The 3BHB006716R0217 synchronous device adopts a reliable design and manufacturing process, which can operate stably under various environmental conditions and has a long service life.

  Flexibility: The 3BHB006716R0217 synchronous device can be programmed and configured to adapt to different application needs and scenarios. Users can customize and adjust according to their actual needs.

  Quasi synchronous method: This device adopts a quasi synchronous method, which means that before being integrated into the power grid, the generator speed and excitation device are adjusted to make the generator speed and voltage close to the system value, and the generator outlet circuit breaker is selected to close at the time of zero phase angle difference to ensure that the generator is quickly pulled into synchronous operation with the minimum impulse current.

  Ideal quasi synchronous conditions:

  The voltage amplitude on both sides of the circuit breaker is equal, i.e. Ug=Us.

  The voltage frequency on both sides of the circuit breaker is equal, that is, ω g=ω s or fg=fs.

  The phase angle difference at the moment when the circuit breaker closes is zero, that is, phi=0, ensuring that the impact current of the system on the generator at the moment of grid connection is zero.

  Application scenarios:

  The 3BHB006716R0217 synchronous device is widely used in power stations, industrial production equipment, distribution systems, and other situations that require generators to be connected to the grid. Whether in manual or fully automatic grid connection, the device can effectively perform its various functions.

  Notes:

  When using the 3BHB006716R0217 synchronous device, it is necessary to ensure that the operator has the corresponding professional knowledge and skills to ensure the safety and accuracy of grid connection operation.

  Before conducting grid connection operations, it is necessary to carefully check the various parameters and settings of the device to ensure that they match the actual situation.

  During the grid connection process, it is necessary to closely monitor the operating status and monitoring data of the device, and promptly detect and handle abnormal situations.

  In summary, the 3BHB006716R0217 synchronous device is a powerful and technically reliable power system equipment that can effectively achieve the parallel operation of the generator and the power grid, ensuring the stable operation of the power system and the safe use of the generator.


  All products on this website are special products, and market prices have been fluctuating,

  The specific customer service quotation shall prevail, as the product is a new product and the price is not genuine,

  Please confirm the model, product, price, and other detailed information with customer service before placing an order. The website has been used,

  The new one is for sale, please contact customer service to communicate.


Discounted product recommendations:

SYN5302-5287
SYN5302-5281
SYN5302-5277
SYN5302-5271
SYN5302-4287
SYN5302-4281
SYN5302-4277
SYN5302-4271
SYN5302-3287
SYN5302-3281
SYN5302-3277
SYN5302-3271
SYN5302-2287
SYN5202-5271
More......

PRODUCT TAGS

Shanxi Runsheng Import and Export Co., Ltd

Address: 3301, Building A, Wanda Center, No. 175 Jiefang Road, Xinghualing District, Taiyuan City, Shanxi Province
Google email: wkcarshop666888@gmail.com
Industrial Control Sales Consultant: Amelia
Whatsapp: +86 18030295882

Copyright © 2023~2024 Shanxi Runsheng Import and Export Co., Ltd